1/3 PHASE CONTROLLERS

MODELS Low&High
Volt
Protection
Dry Run
Overload
Protection
Delay
on
Timer
Dry
Run
Restart
Timer
Cyclic
Timer
Maximum
Run Timer
Single
Phasing
Preventer
3010 1/3 PHASE 1CT BSS
3010 1/3 PHASE 1CT BSD
3010 1/3 PHASE 3CT BSD
AUTO CAPACITOR CHANGE OVER - SSN

3010 1/3 PHASE 1CT BSS

NIAGARA - AGRICULTURAL AUTOMATION

Suitable For

Three Phase Pumps

Features

  • Adjustable Star to Delta Time.
  • 2 & 3 Phase Operations.
  • Low / High Voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run / Restart timer Facility.
  • Delay On Timer.
  • Cyclic Timer.
  • Adjustable Voltage & Current Setting.
  • Micro Controller based Single Phase Preventer(SPP).
  • Seven Segment LED Display Indication.

Technical Specifications

Description Rating
Operating Voltage (AC) 3∅ - 300V to 470V
Operating Voltage for float Sensor Min 12V to Max 30V DC
Calibration accuracy +/- 5%
Dimension L 150 X W 150 X H 100 mm
Operating Current For Load
Relay Load 3∅ - 10 Amp
Motor Rating**
Indirect Load *** Any Size

3010 1/3 PHASE 1CT BSD

NIAGARA - AGRICULTURAL AUTOMATION

3010 1/3P BSD 1CT

Suitable For

Three Phase Pumps

Features

  • Adjustable Star to Delta Time.
  • 2 & 3 Phase Operations.
  • Low / High Voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run / Restart timer Facility.
  • Delay On Timer.
  • Cyclic Timer.
  • Adjustable Voltage & Current Setting .
  • Micro Controller based Single Phase Preventer(SPP).
  • LCD Display Indication.

Technical Specifications

Description Rating
Operating Voltage (AC) 3∅ - 300V to 470V
Operating Voltage for float Sensor Min 12V to Max 30V DC
Calibration accuracy +/- 5%
Dimension L 150 X W 150 X H 100 mm
Operating Current For Load
Relay Load 3∅ - 10 Amp
Motor Rating**
Indirect Load *** Any Size

3010 1/3 PHASE 3CT BSD

NIAGARA - AGRICULTURAL AUTOMATION

3010 1/3P BSS 1CT

Suitable For

Three Phase Pumps

Features

  • Adjustable Star to Delta Time.
  • 2 & 3 Phase Operations.
  • Low / High Voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run / Restart timer Facility.
  • Delay On Timer.
  • Cyclic Timer.
  • Adjustable Voltage & Current Setting .
  • Micro Controller based Single Phase Preventer(SPP).
  • LCD Display Indication.

Technical Specifications

Description Rating
Operating Voltage (AC) 3∅ - 300V to 470V
Operating Voltage for float Sensor Min 12V to Max 30V DC
Calibration accuracy +/- 5%
Dimension L 150 X W 150 X H 100 mm
Operating Current For Load
Relay Load 3∅ - 10 Amp
Motor Rating**
Indirect Load *** Any Size

AUTO CAPACITOR CHANGE OVER - SSN

NIAGARA - AGRICULTURAL AUTOMATION

AUTO CAPACITOR CHANGE OVER - SSN

Features

  • It has 4 Relay adjustments.
  • Based on voltage value it will automatically switch ON the Relay.
  • It will step up or step down the voltage using capacitor for 2 phases.
  • Seven Segment LED Display Indication.

Technical Specifications

Description Rating
Operating Voltage 300V to 470V AC
Dimension L 130 X W 90 X H 70 mm