MODELS Top
Tank
Level
Bottom
Tank
Level
Low&High
Volt
Protection
Dry Run
Overload
Protection
Delay
on
Timer
Dry Run
Restart
Timer
Cyclic
Timer
Real
Time
Cyclic
Timer
Maximum
Run Timer
Dry
Run
Sensor
1000 S BON
1000 S BSN
1010S BSS
1010 S BSD
1010 S BOD
1010 S DOUBLE BOD

1000 S BON

NIAGARA - WATER LEVEL CONTROLLER

Suitable For

Single Phase Submersible Pumps

Features

  • Switch off the water pump when the upper tank is full/when the sump is empty.
  • Switch on the water pump when the upper tank is empty and when the sump has enough water.
  • Top/Bottom Tank Level Control.
  • Starting Capacitor Delay Timer.
  • Power on delay timer.

Technical Specifications

Description Rating
Operating Voltage (AC) 1∅ - 150V to 270V
Operating Voltage for Float Sensor Min 12V DC
Dimension L 150 X W 55 X H 350 mm
Operating Current For Load
Relay Load 1∅ - 20 Amp
Motor Rating**
Direct Load 1∅ - 2 HP
Indirect Load *** Any Size

1000 S BSN

NIAGARA - WATER LEVEL CONTROLLER

1000s BSN

Suitable For

Single Phase Submersible Pumps

Features

  • Switch off the water pump when the upper tank is full/when the sump is empty.
  • Switch on the water pump when the upper tank is empty and when the sump has enough water.
  • Top/Bottom Tank Level Control.
  • Starting Capacitor Delay Timer.
  • Power on delay timer.

Technical Specifications

Description Rating
Operating Voltage (AC) 1∅ - 150V to 270V
Operating Voltage for Float Sensor Min 12V DC
Dimension L 150 X W 150 X H 100 mm
Operating Current For Load
Relay Load 1∅ - 20 Amp
Motor Rating**
Direct Load 1∅ - 2 HP
Indirect Load *** Any Size

1010 S BSS

NIAGARA - WATER LEVEL CONTROLLER

1010S BSS

Suitable For

Single Phase Submersible Pumps

Features

  • Top Tank Level Control.
  • Bottom Tank Level Control.
  • Low / High Voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run Restart Timer Facility.
  • Delay On Timer.
  • Cyclic Timer.
  • Seven Segment LED Display Indication.
  • Adjustable Voltage & Current Settings.

Technical Specifications

Description Rating
Operating Voltage (AC) 1∅ - 150V to 270V
Operating Voltage for Float Sensor Min 12V DC
Calibration accuracy +/- 5%
Dimension L 150 X W 150 X H 100 mm
Operating Current For Load
Relay Load 1∅ - 20 Amp
Motor Rating**
Direct Load 1∅ - 2 HP
Indirect Load *** Any Size

1010 S BSD

NIAGARA - WATER LEVEL CONTROLLER

1010 SBSD

Suitable For

Single Phase Submersible Pumps

Features

  • Top Tank Level Control.
  • Bottom Tank Level Control.
  • Low / High Voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run Restart Timer Facility.
  • Delay On Timer.
  • Cyclic Timer & RTC Timer.
  • LCD Display Indication.
  • Adjustable Voltage & Current Settings.

Technical Specifications

Description Rating
Operating Voltage (AC) 1∅ - 150V to 270V
Operating Voltage for Float Sensor Min 12V DC
Calibration accuracy +/- 5%
Dimension L 150 X W 150 X H 100 mm
Operating Current For Load
Relay Load 1∅ - 20 Amp
Motor Rating**
Direct Load 1∅ - 2 HP
Indirect Load *** Any Size

1010 S BOD

NIAGARA - WATER LEVEL CONTROLLER

1010S BOD

Suitable For

Single Phase Submersible Pumps

Features

  • Switch off the water pump when the upper tank is full/when the sump is empty.
  • Switch on the water pump when the upper tank is empty and when the sump has enough water.
  • Switch off the water pump during low voltage and high voltage and automatically switch on during normal voltage.
  • Switch Off the water pump during dry run and overload.
  • User-friendly LED and LCD indication display.
  • Adjustable voltage and current settings.

Technical Specifications

Description Rating
Operating Voltage (AC) 1∅ - 150V to 270V
Operating Voltage for Float Sensor Min 12V DC
Calibration accuracy +/- 5%
Dimension L 150 X W 55 X H 350 mm
Operating Current For Load
Relay Load 1∅ - 20 Amp
Motor Rating**
Direct Load 1∅ - 2 HP
Indirect Load *** Any Size

1010 S DOUBLE BOD

NIAGARA - WATER LEVEL CONTROLLER

1010 S DOUBLE BOD

Suitable For

Single Phase Submersible Pumps

Features

  • Switch off the water pump when the upper tank is full/when the sump is empty.
  • When sump empty tank motor will turn off and bore motor will turn on.
  • Switch on the water pump when the upper tank is empty and when the sump has enough water.
  • Switch off the water pump during low voltage and high voltage and automatically switch on during normal voltage.
  • Switch Off the water pump during dry run and overload.
  • User-friendly LED and LCD indication display.
  • Adjustable voltage and current settings.
  • Using one controller can operate two pumps.

Technical Specifications

Description Rating
Operating Voltage (AC) 1∅ - 150V to 270V
Operating Voltage for Float Sensor Min 12V DC
Calibration accuracy +/- 5%
Dimension L 150 X W 55 X H 350 mm
Operating Current For Load
Relay Load 1∅ - 20 Amp
Motor Rating**
Direct Load 1∅ - 2 HP
Indirect Load *** Any Size